KFB/KFN-TM-BA_IA-e-1624 29
7.7.1 Tolerance check for target weight
Settings
Press and at the same time in weighing mode.
Press until the display for entering the lower limit value
appears.
Press , the current setting will be displayed.
To enter the lower limit, e. g. 1000 Kg, press the navigation
keys (See chap. 2.1.1); the currently enabled digit will be
flashing.
Confirm input by .
Press repeatedly until is displayed.
Press , the current setting for the upper limit will be
displayed.
Press the navigation keys (See chap. 2.1.1) to enter the
upper limit, e.g. 1,100 kg; the currently enabled digit will be
flashing.
Confirm input by .
Press repeatedly until is displayed.
Press