Keyscan CA8WL-AL - Figure 12 - Communication - Network with Poe (Ethernet)

Default Icon
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Keyscan Inc. A Member of the Kaba Group CA8WL-AL Rev. B Installation Guide (07.15)
25
Figure 12 - Communication Network with PoE (Ethernet)
For a non-PoE Ethernet connection, also refer to the CA8WL-AL Power Supply Connections diagram. In a non-
PoE application, the PIM400-485 may be powered from the CA8WL-AL’s Power – Out terminal or directly from
the power supply.
POWER
INOUT
-
+
-
+
DOOR
AUX.
N/C
(+)
COM
(-)
N/O
(+)
N/C
(+)
COM
(-)
N/O
(+)
RS-485
A
B
RS-232
CTS
DTR
DCD
RD
TD
GND
DOOR
RTE AUX1 AUX2
-
+
-
+
-
+
-
+
READER
2
READER
1
C1
(BEEP)
LE D
D1
WHITE
D0
GREEN
PWR
RED
GND
BLK
C1
(BEEP)
LE D
D1
WHITE
D0
GREEN
PWR
RED
GND
BLK
J4
J1
RDR
RST .
CLR
MEM.
(+ 12 VDC)
J10
J11
J9
J8
DIP Switches
Terminal Block Activation
S1.11 = OFF
S1.10 = ON
Communication
Standard Communication S1.1 = OFF
Reverse Network Communication S1.1 = ON
Bit Rate
115,200 BPS S1.2 = OFF
57,600 BPS S1.2 = ON
to network
Server/workstation
with
communication
service
to network
KI-00533E-12-14
to
Ethernet
terminal
SYS.
RST.
S1
RDR/SUPV. CONFIG.
SYSTEM CONFIG
.
ON
6
7
8
9
10
2
3
4
5
1
6
7
8
9
10
2
3
4
5
1
11 12
ON
to cold water pipe
Ground
Lug
# 18 AWG
Green*
PC1156
RS485
TDA- TDB+RDB
+ POWER -
Cut View of PIM-400
With front cover
removed
A to TDA-
B to TDB+
RS485
CAT 5, 1 twisted pair
maximum 4000 ft.
(1219.2 m)
- Black
+ Red
- Black
+ Red
PoE
Note # 18 AWG Green
- required for either PoE or
ungrounded power supply
- not required for grounded
power supply

Table of Contents