Remote Interface Reference 3
Keysight E364xA User’s and Service Guide 115
System-Related Commands
DISPlay {OFF|ON}
Turn the front-panel display off or on. When the display is turned off, outputs
are not sent to the display and all annunciators are disabled except the ERROR
annunciator.
The display state is automatically turned on when you return to the local
mode. Press (Local) key to return to the local state from the remote
interface.
DISPlay?
Query the front-panel display setting. Returns “0” (OFF) or “1” (ON).
DISPlay:TEXT <quoted string>
This command displays a message on the front panel. The power supply will
display up to 11 characters in a message; any additional characters are
truncated. Commas, periods, and semicolons share a display space with the
preceding character, and are not considered individual characters.
DISPlay:TEXT?
Query the message sent to the front panel and returns a quoted string.
DISPlay:TEXT:CLEar
Clear the message displayed on the front panel.
OUTPut {OFF|ON}
Enable or disable the outputs of the power supply. When the output is
disabled, the voltage value is 0 V and the current value is 20 mA. At *RST, the
output state is OFF.
OUTPut?
Query the output state of the power supply. The returned value is “0” (OFF) or
1” (ON).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies E3640A and is the answer not in the manual?

Keysight Technologies E3640A Specifications

General IconGeneral
BrandKeysight Technologies
ModelE3640A
CategoryPower Supply
LanguageEnglish

Related product manuals