Base Matrix Configuration 2
Keysight 34934A User’s Guide 61
In “Placing Safety Interlock Continuity Jumpers on the 34934C-001 Configuration
Block” on page 58, you will have installed the supplied blue terminators in the live
headers on the configuration block.
You can now make row connections to these headers, by utilizing the central 16
pins (3-18) on the snap-in terminators. The extension header’s supplied
terminator is shown below. Pay careful attention to the polarizing notches for
identification of pin 1:
You must fabricate custom cabling to make row signal connections to the central
16 pins (3-18) of these headers, using the pin assignments below. The supplied
blue terminators accommodate 22 AWG coated wire, fitted to “crimp-to-wire”
contacts with latch tabs (FCI part #76357-301LF or equivalent).
34934C-001: Extension Header Pin Assignments for 4x32