EasyManua.ls Logo

Keysight E3632A - Installation Procedure for an External Relay

Keysight E3632A
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2Service
64 Keysight E3632A Service Guide
Installation procedure for an external relay
The assembly drawings are located in “Component Locator Diagram” on page 71.
1 Remove the front and rear bumpers and take off the cover.
2 Install JP3
[1]
and JP4
[1]
located adjacent to the connector P5 (refer to
“Component locator diagram for the main board assembly — top” on page 71).
A bare wire may be used.
3 Reassemble the power supply.
[1] For serial MY53xx6xxx, install JP751 and JP752 located adjacent to the connector CN751 (refer to
“Component locator diagram for the main board assembly — top (serial MY53xx6xxx)” on page 73
on page 63)