Parameter Typical Return
0|OFF|1|ON, *RST OFF 0or1
Enable resistance in voltage priority mode: VOLT:RES:STATON, (@1)
l This command replaces the previous RESistance:STATe command and should be used in new
applications. RESistance:STATe is still available for backward compatibility.
[SOURce:]VOLTage:SLEW[:POSitive][:IMMediate] <value>, (@<chanlist>)
[SOURce:]VOLTage:SLEW[:POSitive][:IMMediate]? [MIN|MAX,] (@<chanlist>)
[SOURce:]VOLTage:SLEW:NEGative[:IMMediate] <value>, (@<chanlist>)
[SOURce:]VOLTage:SLEW:NEGative[:IMMediate]? [MIN|MAX,] (@<chanlist>)
Sets the voltage slew rate. The slew rate is set in volts per second and affects all programmed
voltage changes, including those due to the output state turning on or off. The slew rate can be set to
any value between 0 and 9.9E+37. For very large values, the slew rate will be limited by the analog
performance of the output circuit. The keywords MAX or INFinity set the slew rate to maximum.
Parameter Typical Return
0 9.9E+37|MIN|MAX|INFinity, *RST MAX <slew rate>
Sets the output slewrate to 5 V per second: VOLT:SLEW 5, (@1)
Sets the negative output slewrate to 5 V per second: VOLT:SLEW:NEG 5, (@1)
l The query returns the value that was sent. If the value is less than the minimum slew rate, only
the minimum value is returned. The resolution of the slew setting is also the minimum value, which
can be queried using VOLTage:SLEW? MIN. The exact value varies slightly based on calibration.
l The query returns the programmed slew rate in the form +n.nnnnnnE+nn for each channel spe-
cified. Multiple responses are separated by commas. If a slew rate of 9.9E37 is returned, it means
that the maximum or fastest slew rate has been set.
[SOURce:]VOLTage:SLEW:COUPle 0|OFF|1|ON, (@<chanlist>)
[SOURce:]VOLTage:SLEW:COUPle? (@<chanlist>)
Sets the voltage slew tracking state.
Parameter Typical Return
0|OFF|1|ON, *RST OFF 0or1
Enables the voltage slewtracking state: VOLT:SLEW:COUP ON, (@1)