Do you have a question about the Keysight N9918A and is the answer not in the manual?
Amplitude Accuracy | ±0.5 dB |
---|---|
Tracking Generator | Yes |
Vector Network Analyzer (VNA) | Yes |
Cable and Antenna Analyzer (CAT) | Yes |
Power Meter | Yes |
GPS Receiver | Yes |
Operating Temperature | -10 °C to +50 °C |
Resolution Bandwidth (RBW) | 1 Hz to 3 MHz |
Measurement Types | Spectrum Analyzer, Vector Network Analyzer, Cable and Antenna Analyzer, Power Meter |
Battery Life | Up to 4 hours |
Interface | USB, LAN |
Display | 8.4-inch color touchscreen |
Storage Temperature | -40 °C to +70 °C |
Information regarding the material contained in this document and Keysight's warranty obligations.
Describes how to power the FieldFox ON, switch to Standby mode, and power OFF.
Covers settings for CAT mode, including measurement selection and frequency range.
Step-by-step guide on performing Distance to Fault measurements on a cable.
Explains settings for DTF measurements, including format, start/stop distance, and frequency mode.
Step-by-step guide on performing Time Domain Reflectometry measurements.
Details on selecting the display format for TDR measurements.
Covers settings for Network Analyzer mode, including S-parameters and trace configurations.
Details on setting up Time Domain transform, including frequency range and points.
Step-by-step guide on performing instrument calibration.
Covers settings for Spectrum Analyzer mode, including frequency range and radio standards.
Configuration settings specific to the RTSA mode.
Settings for the I/Q Analyzer mode, including measurement selection and data display.
Guide to performing measurements using the I/Q Analyzer mode.
Overview of connecting the FieldFox to PC-based software via LAN for remote operation.
Settings for using the SA input connector for power measurements without a sensor.
Settings for using USB power sensors for power meter measurements.
Settings for performing pulse measurements.
Settings for the Vector Voltmeter mode.
Guides through the physical setup for ERTA measurements.
Selecting measurement settings like frequency range and points for ERTA.
Demodulating and characterizing AM and FM signals.
Functionality overview of the Channel Scanner feature.
Steps to set up a channel scan measurement.
Overview of Noise Figure measurement capabilities and features.
Step-by-step procedure for defining and setting up a noise figure measurement.
Information on creating, moving, and using markers for trace analysis.
Procedure for creating and activating markers on a trace.
Steps to save the current screen or a saved file.
General safety warnings and precautions for operating the FieldFox.