164                                                                                                                     Keysight N9927-90001 User’s Guide
SA (Spectrum Analyzer) Mode
SA Mode Settings
Video Bandwidth (Video BW)
Video BW is a smoothing operation that is performed after measurement data 
is acquired. The trace data is effectively smoothed so that the average power 
level of the displayed noise is the same, but the peaks and valleys of adjacent 
data points are smoothed together. More smoothing occurs as the Video BW is 
set lower. However, as the Video BW is narrowed, the sweep speed becomes 
slower.
How to set VBW
—Press BW 2.
—Then Video BW
— Then choose from the following:
—Auto
 Couples Video BW to the ResBW in a 1-to-1 ratio. 
—Man
 Enter a Video BW value using the numeric keypad, the   
arrows, or the rotary knob. Then press a multiplier if necessary or 
press Enter
. Setting VBW higher than RBW may smooth the trace.
.
The current Video BW setting is shown at the bottom of the screen. 
# VBW x.xx XHz (#) means manual setting. 
When the Res BW/Video BW ratio exceeds 10,000, a Meas UNCAL warning 
may appear to indicate that the Video BW filter has reached the maximum 
capacity for averaging.
Sweep Type
In SA mode, the FieldFox uses two sweep types to process inputs signals. The 
sweep type that is currently being used (FFT or Step) is displayed in the 
lower-left corner of the FieldFox screen. 
For a more comprehensive tutorial, see Spectrum Analysis Basics (App Note 
150) at http://literature.cdn.keysight.com/litweb/pdf/5952-0292.pdf
How to set Sweep Type
—Press BW 2.
—Then Advanced
—Then Sweep Type
— Then choose from the following:
To change this setting from Man to Auto, press Video BW twice.