280                                                                                                                     Keysight N9927-90001 User’s Guide
Interference Analyzer (SA Mode) – Option 236
Record/Playback (SA Option)
—Then Record Playback
—Then New Session or Recall an existing session.
If New Session
 is selected:
—Then Session Data
 and choose one of the following:
—Then CSV SaveStyle
——Single Trace (default) saves the currently displayed trace.
——Range Traces
 saves the currently displayed trace. This 
selection requires you to manually select a range of traces to 
be recorded in the Playback Configuration menu. Refer to 
“Playback Configuration” on page 283.
——AllTraces
 saves all traces.
—Then TraceRecordLimit
 to change the maximum recording file size.
—Then Clear AllRecords
 to clear all traces out of memory.
—Then Back
 to return to previous menu.
—Then Recording Configuration
Then choose from the following:
— Record Time
 Sets the amount of time to record traces. Default is MAX, 
which is to record indefinitely. Enter a value between 1s and 1 Ms (million) 
seconds using the numeric keypad,   arrows, or the rotary knob. When 
set, a timer appears during recording in the lower-left corner which counts 
DOWN from the specified time.
— Record Source
 Sets where, in the FieldFox data flow, data is recorded. 
Learn more in “Record Source” on page 282. Choose from the following:
— RawMeas
 Records raw measurement data.
— Trace 1,2,3,4
 Records data from the corresponding trace in its 
current state. 
— Record Interval
 Sets the amount of time to wait between individual trace 
recordings. Default is MIN, which is to wait 0 seconds (record traces as fast 
as possible). Enter a value in seconds between 0 (no delay) and 10,000 
seconds - about 3 hrs) using the numeric keypad,   arrows, or the rotary 
knob. 
— Segment Count
 Sets the number of traces to record, after which the 
recording will automatically pause. Press Pause/Resume or Record to 
capture another N traces, or Stop to end recording. Default is OFF, which is 
NO limit to the number of traces to be recorded. 
When set, a counter appears in the lower-left corner which counts UP to 
the specified number of recordings.