Powering
up with the load turned on
(CONFIG number
8)
Set whether to turn
on/off
the load at power
on.
Selectable Values
Description
ON Automatically turn the
load on at power
on
OFF Keep the
load turned off at
power
on
Communication function
selection (CONFIG number
9)
Select GPIB
or RS-232C.
Selectable Values Description
GPIB GPIB
232 RS-232C
•
After changing the setting, power cycle the PLZ-U. The new setting takes effect
by power cycling.
Setting the GPIB address (CONFIG
number
10)
Set the GPIB address.
Selectable Values Description
i to 30 GPIB address
•
After changing the setting, power cycle the PLZ-U. The new setting takes effect
by power cycling.
RS-232C baud rate setting (CONFIG
number
11)
Set the RS-232C baud rate.
Selectable Values Description
2400 2400 bps
4800 4800 bps
9600 9600 bps
19200 19200 bps
•
After changing the setting, power cycle
the PLZ-U. The
new
setting takes
effect
by
power
cycling.
5-20
Application
Operation PLZ-U