TOS8870A Table of Contents IX
Chapter 3 OPERATION PROCEDURE
3.1 Procedure Before Test ..................................................................................... 12
1) Check that the indicator...................................................................................................12
2) Confirmation of attention on the handling ......................................................................12
3) Reset the Tester ...............................................................................................................12
3.2 Single Withstanding Voltage Test .................................................................... 12
1) Selecting the withstanding voltage test mode .................................................................12
2) Selecting a test voltage range ..........................................................................................12
3) Setting the high limit reference value of leakage current................................................12
4) Setting the test time .........................................................................................................13
5) Setting the test voltage.....................................................................................................13
6) Connecting the DUT........................................................................................................13
7) Test procedure .................................................................................................................14
8) Single test without using the timer ..................................................................................14
9) Reapplication of test voltage (retest)...............................................................................14
10) Setting the PASS-FAIL judgement reference values for withstanding voltage test......14
11) Setting the LOWER REFERENCE value .....................................................................15
3.3 Single Insulation Resistance Test .................................................................... 17
1) Selecting the insulation resistance test mode ..................................................................17
2) Check the Zero-ohm ........................................................................................................17
3) Selecting a test voltage ....................................................................................................17
4) Setting the PASS-FAIL judgement reference values for Insulation resistance test ........17
5) Setting the test time .........................................................................................................18
6) Connecting the DUT........................................................................................................18
7) Test procedure .................................................................................................................19
8) Test without using the timer ............................................................................................19
9) Reapplication of test voltage (retest)...............................................................................19
10) Checking discharge from DUT .....................................................................................19
3.4 Automatic Test ................................................................................................. 20
1) Selecting a test sequence .................................................................................................20
2) Setting the test conditions................................................................................................20
3) Connecting the DUT........................................................................................................20
4) Test procedure .................................................................................................................20
5) To abort the test ...............................................................................................................20
6) Reapplication of test voltage (retest)...............................................................................20
7) Checking discharge from DUT .......................................................................................20
3.5 Remote Control ................................................................................................ 21
1) Remote-control with the option.......................................................................................21
2) Remote-control by the other control system ...................................................................21
3) INTERLOCK terminal ....................................................................................................23
3.6 Output Signals.................................................................................................. 23
3.7 Special Test Modes.......................................................................................... 26