48 A-61626 January 2010
Images - Sent To Application — saves the images received at the
scanning application from the scanner.
Simulation — allows you to use the TWAIN Datasource without using
the actual scanner.
Model: allows you to select the specific model to simulate.
Flatbed: allows you to select which flatbed accessory to simulate.
Flags: if supported by your TWAIN Datasource, this will contain a list
of accessories your simulate scanner has installed.
Diagnostics - Logs tab The Logs tab allows you to view scanner information.
Logs
General: displays the scanner's version information, serial number,
attached/installed accessories, meters, etc.
Operator: displays the scanner's log. This log can only be cleared by
your support personnel.
Toolbar buttons
Save As — saves all the logs for viewing by support personnel.
When selected, the Save As window will displayed:
Folder: the location to save the logs.
Browse: displays the operating system's File Open window so
you can find the folder that you want to use.
Include debug images: includes any generated debug
images with the logs. This is turned on by default and should
only be turned off when recommended by your support
personnel.
Save: saves the logs into a file with the extension .eklog.
Refresh: refreshes the currently displayed log.