8.33
8
Section 8
Electrical System and Components
Figure 8-54. Removing Retaining Ring.
12. Remove the drive pinion assembly from the
armature.
13. Clean the parts as required.
NOTE: Do not soak the armature or use solvent
when cleaning. Wipe clean using a soft cloth,
or use compressed air.
Figure 8-53. Retaining Ring Detail.
11. Remove the retainer from the armature shaft.
Save the stop collar.
NOTE: Do not reuse the old retainer.
Lever
Solenoid
CE Frame
Bolt
Ring
Stop
Drive
Armature
Washer
Screw
Plunger
Spring
Plate
Collar
Tube
Screw
Plug
Frame & Field
Brush Holder
Nut
Figure 8-55. Delco-Remy Starter.