qb701 User’s Manual
10
4
1
3
2
5
1
MOUNTING TRANSDUCERS
Firmly tighten rods 1 into the shaft brackets 2.
Put thumb nut 3 into the bracket 2, then hook the chain 5 on the stud 4.
Firmly tighten the thumb nut 3. Shaft brackets with rods must be mounted at the
same angular position.
Mount transducers on the rods. Always try to mount transducers at minimal
possible radial height. Make sure that transducers are not touching brackets or
machine parts.
S, M transducers to be
installed at the same
height with labels faced up
Datum lines for measuring
of dimension input
Locking
thumb nut
M transducer
installed on
the machine
to be moved
S transducer
installed on
the stationary
machine