HORIZONTAL MACHINE ALIGNMENT
SHORT EXPLANATION
o Mount transducers on shafts
o Run Horizontal program
o Enter dimensions
o Set parameters. E.g. Measurement mode clock type (9-12-3 o’clock positions)
o Turn shafts with transducers at first position 9 o’clock (90°). Press Start to take
readings
o Turn shafts with transducers at second position 12 o’clock (180°). Press Start to
take readings
o Turn shafts with transducers at last position 3 o’clock (270°). Press Start to take
readings
o After that device will calculate misalignment and displays required corrections for
Movable machine
TRANSDUCERS POSITIONS CONVENTIONS
While taking measurements, it is necessary to
follow conventions for transducers positions on
the shafts with the S and M measuring
transducers with regard to the relative position of
the S and M machines as depicted on the figure.
Angular positions in degrees adopted in the
device are as follows:
6 o’clock -
9 o’clock - 90°
12 o’clock - 180°
3 o’clock - 270°