qb701 User’s Manual
34
MACHINE CORRECTION @45
In order to exclude the need to turn the shafts when switching
correction plane, transducers can be placed at one of 45°
positions: 10:30, 1:30, 4:30, 7:30 o’clock. This option can be used
on Horizontal and Vertical machines.
Use arrows keys to choose position at which transducers
will be placed, then press key.
Live alignment at 12-6 plane.
Press key to choose 9-3 plane.
There is no need to turn shafts in this mode.
Transducers can be at static 45° position.
Color of coupling signs indicates value of misalignment. Green color indicates when
residual misalignment is within tolerance. Black color is for perfect result. Always stop
machine correction when residual misalignment is within tolerance. Do not try to reach
zero.