qb701 User’s Manual
17
Press - to toggle data input – LD transducer’s data / MD – manual data
Press - to toggle angle input – IA use inclinometer / MA manual angle. Manual angle
input used for vertical machines, when electronic inclinometer cannot be used.
Press - to toggle displayed precision – 2 or 3 digit.
Press then - to toggle measurement
mode:
Turn 3 - clock mode 9-12-3 o’clock – readings
to be taken at three predefined shaft positions – 9
o’clock, then 12 o’clock, then 3 o’clock. After that,
device will proceed to the result screen.
Turn 4 points – readings to be taken at four
predefined shaft positions separated by 90° or 45° (3hr / 1:30hr). After that the device
will proceed to the result screen.
Multipoint mode – measurements may be taken at any of minimum 3 up to 36 positions.
After taking enough readings one should press to proceed to the result screen.
TOLERANCE SETUP
Press to enter tolerance setup menu.
Press to use predefined RPM/tolerance table
Press to enter user defined tolerance values
Press to save changes, to discard changes.