TAKING MEASUREMENTS. MULTIPOINT MODE
In multipoit mode readings can be collected at any shafts position minimum 3 up to 36
positions.
qb701 is able to calculate misalignment after collecting at least 3 points within as little as
70 degree range. However always try to cover as wide shaft turn angle as possible.
Press to take reading, and then turn
shafts to next position.
Yellow clock face means that point is already
collected and shafts should be turned to next
position.
When enough readings are collected press to proceed to the
result screen.
TAKING READINGS. AUT O SHOOTING MODE
Turn shafts to first
position, then press
key to activate auto shooting mode.
When auto shooting mode is active device
waits for stable shaft position then
automatically records data and prompts to
move shafts to the next position.
Auto shooting