qb701 User’s Manual
29
VERTICAL MACHINE ALIGNMENT
SHORT EXPLANATION
o Mount transducers on shafts
o Run Vertical program
o Mark on the machine three positions spaced by 90° (9-12-3 o’clock positions)
o Enter dimensions
o Set parameters. E.g. Tolerances.
o Turn shafts with transducers at first position 9 o’clock (90°). Press Start to take
readings
o Turn shafts with transducers at second position 12 o’clock (180°). Press Start to
take readings
o Turn shafts with transducers at last position 3 o’clock (270°). Press Start to take
readings
After that device will calculate misalignment and displays required corrections for Movable
machine
TRANSDUCERS POSITIONS CONVENTIONS
While taking measurements, it is necessary to follow
conventions for transducers positions on the shafts with
the S and M measuring transducers with regard to the
relative position of the S and M machines as depicted on
the figure.
Angular positions in degrees adopted in the device are as
follows:
6 o’clock -
9 o’clock - 90°
12 o’clock - 180°
3 o’clock - 270°
The electronic inclinometers cannot be used on the vertical machines, so “Manual angle” is
set by default. One should mark measurement positions on the machine prior to start
measuring.