7.
Slide filter (6) down, and remove spacer (5) from filter re-
moval tool (3).
8.
Pull filter (6) up while pushing in the tip of filter removal
tool (3), and remove it.
9.
Return the removed spacer (5) to filter removal tool (3),
and keep them.
10.
Insert a new filter and a new element into the bottom of
DEF pump, and lightly tighten them with hand.
11.
Tighten filter cap (1).
Tightening torque: 20 to 25 Nm {2.0 to 2.5 kgm}