Komatsu HM400-5 - Method for Performing Calibration

Komatsu HM400-5
446 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.
Select “Machine ID Setting”.
The set machine ID is displayed on the right side.
3.
Press enter switch (2).
The pop-up window opens and displays the currently set
machine ID. Input the machine ID.
The settable range is from 0 to 200.
Each time Up switch (3) is pressed, ID increases by 1.
Each time Down switch (4) is pressed, ID decreases
by 1.
If Up switch (3) is held down, ID increases rapidly. If
Down switch (4) is held down, ID decreases rapidly.
If UP switch (3) is pressed when 200 is displayed as
ID, ID returns to 0. If Down switch (4) is pressed when 0 is displayed as ID, it becomes 200.
4.
After inputting the machine ID, press enter switch (2).
The value at this time is set as ID, and the windows closes.
If you press return switch (5), the window closes without changing the value of ID.
5.
When setting an open ID, select “Open ID Setting” on the
screen of step 2.
The set open ID is displayed on the right side.
6.
The setting procedure for the open ID is the same with the
machine ID.
Set the open ID.
METHOD FOR PERFORMING CALIBRATION
Perform calibration in the following cases.
When the machine or payload meter is delivered
Once a month
When the suspension cylinder gas pressure and oil quantity are adjusted (When the suspension is adjus-
ted)
ATTACHMENTS AND OPTIONS HANDLING PAYLOAD METER