10 Structure, function and maintenance standard SEN00176-02
114E-3 Series
35
Unit: mm
No. Check item Criteria Remedy
1 Face runout of flywheel housing Repair limit: 0.20
Reassemble,
correct
2 Radial runout of flywheel housing Repair limit: 0.20
3
Tightening torque of flywheel housing
mounting bolt
Target (Nm {kgm})
Tighten
77 {7.85}
4 Face runout of flywheel
Flywheel Limit
Reassemble,
correct
For clutch 0.013 / ø25.4
For torque
converter
Diameter (actual measurement) × 0.0005
5 Radial runout of flywheel Repair limit: 0.13
6
Tightening torque of flywheel mounting
bolt
(Coat bolt thread with engine oil)
Target (Nm {kgm})
Tigthen and
retighten
137 {14.0}