SEN00459-01 40 Troubleshooting
32 114E-3 Series
E-19 Code [272/CA272] IMV (IMA) Open Error 1
Error code Failure code
Trouble Disconnection in IMV (IMA)
272 CA272
Contents of
trouble
There is disconnection in supply pump actuator drive circuit.
Action of
controller
None in particular.
Problem that
appears
on machine
Engine speed runs, but in unstable condition.
Common rail fuel pressure is above command value.
Related infor-
mation
Method of reproducing failure code: Starting switch ON.
Possible
causes and
standard value
in normal state
Causes Standard value in normal state/Remarks on troubleshooting
1
Defective supply pump actu-
ator
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
CP3 PUMP REGULATOR (Male) Resistance
Between (1) – (2) Max. 5 z
2
Disconnection in wiring har-
ness (Disconnection in wiring
or defective contact in con-
nector)
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between J1 (female) (2) –
CP3 PUMP REGULATOR (female) (1)
Resis-
tance
Max. 10 z
Wiring harness between J1 (female) (32) –
CP3 PUMP REGULATOR (female) (2)
Resis-
tance
Max. 10 z
3
Hot short (Short circuit with
24V circuit) in wiring harness
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
Wiring harness between J1 (female) (2) –
CP3 PUMP REGULATOR (female) (1)
Voltage Max. 3 V
4
Short circuit in wiring har-
ness (with another wiring
harness)
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness among all pins between J1
(female) (2) – J1 (female) (With all connec-
tors of wiring harness disconnected)
Resis-
tance
Min.
100 kz
5
Defective wiring harness
connector
Connecting parts among supply pump actuator, engine wiring har-
ness, and engine controller are suspected.
Inspect them directly.
Loose connector, broken lock, broken seal
Corrosive, bent, broken, forced-in, or extended pin
Humidity in connector, entry of dirt or dust, poor insulation
6 Defective engine controller
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
J1 (Female) Resistance
Between (2) – (32) Max. 5 z