SEN00460-01 40 Troubleshooting
42 114E-3 Series
E-49 Code [2185/CA2185] Throttle Sens. Sup. Volt. High Error 1
Circuit diagram related to fuel control dial
Error code Failure code
Trouble Abnormally high level in throttle sensor
2185 CA2185
Contents of
trouble
• High voltage (min. 5.25 V) occurred in throttle sensor power supply circuit.
Action of con-
troller
• Depends on machine model.
Problem that
appears on
machine
• Depends on machine model.
Related infor-
mation
• Method of reproducing failure code: Starting switch ON.
Possible causes
and standard
value in normal
state
Causes Standard value in normal state/Remarks on troubleshooting
1
Short circuit in wiring har-
ness (With another wiring
harness)
a Troubleshoot with starting switch OFF, then carry out trouble-
shooting without turning starting switch ON.
Wiring harness among all pins between J2
(female) (22) – J2 (female) (With P20 dis-
connected)
Resis-
tance
Min.
100 kz
Between J2 (female) (22) – J3 (female) (3)
(With P20 disconnected)
Resis-
tance
Min.
100 kz
2
Defective wiring harness
connector
Connecting parts among fuel control dial, engine unit wiring har-
ness, and engine controller are suspected. Inspect them directly.
• Loose connector, broken lock, broken seal
• Corrosive, bent, broken, forced-in, or extended pin
• Humidity in connector, entry of dirt or dust, poor insulation
3 Defective engine controller
If causes 1 and 2 are not detected, engine controller may be defec-
tive. (Since trouble is in system, troubleshooting cannot be carried
out.)