SEN00460-01 40 Troubleshooting
52 114E-3 Series
E-55 Code [2555/CA2555] Intake Air Heater Relay Supply Voltage Low
Error 1
Error code Failure code
Trouble Disconnection in intake air heater relay
2555 CA2555
Contents of
trouble
There is disconnection in intake air heater relay.
Action of
controller
None in particular.
Problem that
appears
on machine
Intake air heater does not function
(Poor starting performance, white exhaust smoke at low temperature)
Related infor-
mation
Method of reproducing failure code: Starting switch ON when coolant temperature is –4°C or less.
Possible
causes and
standard value
in normal state
Causes Standard value in normal state/Remarks on troubleshooting
1
Defective auto preheat relay
(Internal disconnection)
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON. (Test relay unit).
R18 (male) Resistance
Between (1) – (2) 300 – 600 z
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting. (Test by replacing relay unit.)
Replace auto preheat relay (R18) with other relay. If mark E of fail-
ure code disappears after reproduction operation is conducted, that
relay has a defect.
2
Disconnection in wiring har-
ness (Disconnection in wiring
or defective contact in con-
nector)
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between J2 (female) (40) –
R18 (female) (1)
Resis-
tance
Max. 10 z
Wiring harness between J2 (female) (42) –
R18 (female) (2)
Resis-
tance
Max. 10 z
3
Short circuit in wiring har-
ness (With another wiring
harness)
a Troubleshoot with starting switch OFF, then carry out trouble-
shooting without turning starting switch ON.
Wiring harness among all pins between J2
(female) (40) – J2 (female) (With also R18
disconnected)
Resis-
tance
Min.
100 kz
4
Defective wiring harness
connector
Connecting parts among auto preheat relay, engine unit wiring har-
ness, and engine controller are suspected. Inspect them directly.
Loose connector, broken lock, broken seal
Corrosive, bent, broken, forced-in, or extended pin
Humidity in connector, entry of dirt or dust, poor insulation
5 Defective engine controller
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
J2 (female) Resistance
Between (40) – (42) 300 – 600 z

Table of Contents

Related product manuals