SEN00460-01 40 Troubleshooting
26 114E-3 Series
E-40 Code [452/CA452] Rail Press. Sensor Low Error 1
Error code Failure code
Trouble Abnormally low level in common rail pressure sensor
452 CA452
Contents of
trouble
• Low voltage occurred in common rail pressure sensor.
Action of con-
troller
• Limits output and continues operation.
Problem that
appears on
machine
• Engine speed or output drops.
• Engine does not start
Related infor-
mation
• Method of reproducing failure code: Starting switch ON.
Possible causes
and standard
value in normal
state
Causes Standard value in normal state/Remarks on troubleshooting
1
Defective sensor power sup-
ply 2 system
If failure code [CA187] is indicated simultaneously, carry out trouble-
shooting for it first.
2
Defective common rail pres-
sure sensor
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
FUEL RAIL PRESS Voltage
Between (3) – (1) Power supply 4.75 – 5.25 V
Voltage is measured with wiring harness connected. Accordingly, if
voltage is abnormal, check wiring harness and controller, too, for
another cause of trouble, and then judge.
3
Ground fault in wiring har-
ness (Short circuit with GND
circuit)
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between J1 (female) (25) –
FUEL RAIL PRESS (female) (2)
Resis-
tance
Min.
100 kz
4
Short circuit in wiring har-
ness (With another wiring
harness)
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between J1 (female) (25) –
FUEL RAIL PRESS (female) (2) and J1
(female) (47) – FUEL RAIL PRESS (female)
(1)
Resis-
tance
Min.
100 kz
5
Defective wiring harness
connector
Connecting parts among common rail pressure sensor, engine wir-
ing harness, and engine controller are suspected. Inspect them
directly.
• Loose connector, broken lock, broken seal
• Corrosive, bent, broken, forced-in, or extended pin
• Humidity in connector, entry of dirt or dust, poor insulation
6 Defective engine controller
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
J1 Voltage
Between (37) – (47) Power supply 4.75 – 5.25 V