KONE Maintenance Method
MX10 / MX20 MCP Procedures - ASME A17.1-2013 / CSA B44-13
© 2014 KONE Corporation PSK8-604-MX10/MX20
All rights reserved.
19 (-) 2014-12-15
8.6.1.6.3 (e): Fuses and fuse holders
Procedure Note
Check to ensure control fuses are securely
mounted, are making good electrical contact, and
are sized properly.
Never replace fuses with wire or current-
carrying devices.
8.6.1.6.5: Fire extinguisher
Procedure Note
Check the expiration date on the fire extinguisher,
if present.
Notify a supervisor if it is out of date.
8.6.4.1.2: Hoist rope lubrication
Procedure Note
Examine the hoist ropes and look for the
following conditions:
• ropes are dry or the lubricant is stiff
• red dust on the ropes or on the floor
• metal dust under the drive sheave or pulleys
• sheave grooves are dry (no oil film on fingertip
when wiping
If any of the conditions in the procedure are
found, lubricate the ropes using Kone wire
rope lubricant (Part # US45786001).