KONE Maintenance Method
MX10 / MX20 MCP Procedures - ASME A17.1-2013 / CSA B44-13
© 2014 KONE Corporation PSK8-604-MX10/MX20
All rights reserved.
64 (-) 2014-12-15
4 Test Procedures (ASME A17.1–2013/CSA B44-13)
This safety inspection procedure was developed according to ASME A17.1 Code and KONE
Corporation safety policies.
Possible differences between this instruction and local safety regulations must be considered. This
will prevent any safety hazards or damage to the product.
This section contains the testing requirements for the KONE KCM831 elevators equipped with
KDL16L or KDM drive and LCE electrification. Contact your supervisor if you are unsure of the
exact procedures to be used for the test you are performing, or if you have any
questions
regarding these procedures.
Safety
All work must be planned to avoid any safety hazards or damage to the product. Follow this
instruction carefully to avoid potentially dangerous situations.
Verify there is NO ONE INSIDE THE CAR OR IN THE HOISTWAY.
DO ALL TESTING WITH HALL CALLS INHIBITED AND AUTOMATIC DOOR OPERATOR
INHIBITED WHERE POSSIBLE. In this mode the elevator is out of group control. This prevents the
inspection from being interrupted, and passengers being trapped in the car.
BEFORE GOING TO THE CAR ROOF, PUSH the car roof STOP BUTTON.
Before resetting the stop button, TURN THE INSPECTION DRIVE UNIT TO “INSPECTION”
POSITION.