5) Perform following measurement procedure three times and record speed each time.
• Use drill motor and rubber wheel to slowly increase speed of governor.
• Use handheld tachometer to measure speed.
• Continue increasing speed until electrical overspeed switch trips.
• Measure and record trip speed.