9) Record value of force required to move rope.
This value is pull through force. Verify
pull through force is within tolerance on
governor data tag.
10) Reset governor as follows:
EcoSystem MR®
OL100: Use lever provided to reset
tripping lever. Reset electrical switch
manually.
OL35: Rotate governor upward to
mechanically reset governor. Manually
reset electrical switch.
MRL
Rotate governor upward to mechanically
reset governor.
Reset electrical switch by moving XM12
2-pin connector to XM12/1-2 RESET
(RETURN) position and push OSG TEST
button to reset governor electrical switch.
Move 2-pin connector back to XM12/2-3
NORMAL position.
11) Reattach governor rope to safety gear.
12) If counterweight governor, perform same test
using above procedures.
13) Turn on pit switch.
14) Turn on mainline disconnect.
15) Return elevator to normal position.