FC‑404NET – Protocol 3000 Commands
Reset device to factory default configuration
This command deletes all user data from the device. The deletion can take some time.
Your device may require powering off and powering on for the changes to take effect.
~nn @MODEL SP model_name CR LF
model_name – string of up to 19 printable ASCII chars
This command identifies equipment connected to Step-in master products and notifies of identity changes to the connected
equipment. The Matrix saves this data in memory to answer REMOTE-INFO requests
Get device protocol version
~nn @PROT-VER SP 3000:version CR LF
version – XX.XX where X is a decimal digit