Page #22 background imageLoading...
Page #22 background image
Kramer Electronics Ltd.
FC404NET Protocol 3000 Commands
20
System Commands
Command
Description
Type
Permission
NAME
Set/get machine (DNS) name
System
Administrator
NAME-RST
Reset machine name to factory default (DNS)
System
Administrator
NAME
Functions
Permission
Transparency
Set:
NAME
Administrator
Public
Get:
NAME?
End User
Public
Description
Syntax
Set:
Set machine (DNS) name
#NAME SP machine_name CR
Get:
Get machine (DNS) name
#NAME? CR
Response
Set: ~nn @NAME SP machine_name CR LF
Get: ~nn @NAME? SP machine_name CR LF
Parameters
machine_name string of up to 14 alpha-numeric chars (can include hyphen, not at the beginning or end)
Response Triggers
Notes
The machine name is not the same as the model name. The machine name is used to identify a specific machine or a network in use
(with DNS feature on)
NAME-RST
Functions
Permission
Transparency
Set:
NAME-RST
Administrator
Public
Get:
-
-
-
Description
Syntax
Set:
Reset machine (DNS) name to factory default
#NAME-RST CR
Get:
-
-
Response
~nn @NAME-RST SP OK CR LF
Parameters
Response Triggers
Notes
Factory default of machine (DNS) name is “KRAMER_” + 4 last digits of device serial number