19
RESET
Functions
Permission
Transparency
Set:
RESET
Administrator
Public
Get:
-
-
-
Description
Syntax
Set:
Reset device
#RESET CR
Get:
-
-
Response
~nn @RESET SP OK CR LF
Parameters
Response Triggers
Notes
To avoid locking the port due to a USB bug in Windows, disconnect USB connections immediately after running this command. If the
port was locked, disconnect and reconnect the cable to reopen the port.
SN?
Functions
Permission
Transparency
Set:
-
-
-
Get:
SN?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device serial number
#SN? CR
Response
~nn @SN SP serial_number CR LF
Parameters
serial_number 14 decimal digits, factory assigned
Response Triggers
Notes
For new products with 14 digit serial numbers, use only the last 11 digits
VERSION?
Functions
Permission
Transparency
Set:
-
-
-
Get:
VERSION?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get firmware version number
#VERSION? CR
Response
~nn @VERSION SP firmware_version CR LF
Parameters
firmware_version XX.XX.XXXX where the digit groups are: major.minor.build version
Response Triggers
Notes