EasyManua.ls Logo

Kramer VS-66H - 10 Kramer Protocol 2000

Kramer VS-66H
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Kramer Protocol 2000
KRAMER: SIMPLE CREATIVE TECHNOLOGY
20
If the request for identification is sent with the INPUT set as 3 or 4, the appropriate machine will send its software version number.
Again, the reply would be the decimal value of the INPUT and OUTPUT - the INPUT representing the number in front of the decimal
point, and the OUTPUT representing the number after it. For example, for version 3.5, the reply to the request to send the version
number would be (HEX codes):
7D 83 85 81 (i.e. 128dec+ 3dec for 2nd byte, 128dec+ 5dec for 3rd byte).
If the OUTPUT is set as 1, then the ASCII coding of the lettering following the machine’s name is sent. For example, for the VS-
7588YC, the reply to the request to send the first suffix would be (HEX codes):
7D D9 C3 81 (i.e. 128dec+ ASCII for “Y”; 128dec+ ASCII for “C”).
NOTE 14 - The number of inputs and outputs refers to the specific machine which is being addressed, not to the system. For example, if
six 16X16 matrices are configured to make a 48X32 system (48 inputs, 32 outputs), the reply to the HEX code
3E 82 81 82 (ie. request the number of outputs)
would be HEX codes
7E 82 90 82
ie. 16 outputs
NOTE 15 When the OVR bit (4th byte) is set, then the “video” commands have universal meaning. For example, instruction 1
(SWITCH VIDEO) will cause all units (including audio, data, etc.) to switch. Similarly, if a machine is in “FOLLOW” mode, it will
perform any “video” instruction.
NOTE 16 - The reply to the “REQUEST WHETHER PANEL IS LOCKED” is as in NOTE 4 above, except that here the OUTPUT is
assigned with the value 0 if the panel is unlocked, or 1 if it is locked.

Related product manuals