19
OPTIMASS 1000 T6 / 1010C T6 with or without heating jacket / insulation
Ambient Temp.
T
amb
°C
Max. medium
temp. T
m
°C
Temperature Class
Max. Surface
Temp. °C
40
45 T6 T80
60 T5 T95
95 T4 T130
130 T3 – T1 T165
50
60 T5 T95
95 T4 T130
130 T3 - T1 T165
65
95 T4 T130
130 T3 - T1 T165
OPTIMASS 1300C T6 with aluminium converter housing & without heating jacket / insulation
Ambient Temp.
T
amb
°C
Max. medium
temp. T
m
°C
Temperature Class
Max. Surface
Temp. °C
40
45 T6 T80
60 T5 T95
100 T4 T130
130 T3 – T1 T155
50
60 T5 T95
100 T4 T130
130 T3 - T1 T160
60 60 T4 - T1 T95
65* 65 T4 - T1 T100
OPTIMASS 1300C T6 with aluminium converter housing & heating jacket / insulation
Ambient Temp.
T
amb
°C
Max. medium
temp. T
m
°C
Temperature Class
Max. Surface
Temp. °C
40
45 T6 T80
60 T5 T95
95 T4 T130
130 T3 – T1 T165
50
60 T5 T95
95 T4 T130
100 T3 - T1 T135
60 60 T4 - T1 T95
65* 65 T4 - T1 T100
2.4 OPTIMASS 1000 T6 / 1010C T6 / 1300C T6
The OPTIMASS 1000 T6 / 1010C T6 / 1300C T6 is suitable for temperature classes T6….T1
according to the following table:
AD OPTIMASS 300_010 Haz Areas Rev 01.qxp 05/03/2014 13:24 Page 19