EasyManua.ls Logo

KROHNE OPTIMASS 8300C - Temperature Limits for OPTIMASS 1000 T6;1010 C T6;1300 C T6

KROHNE OPTIMASS 8300C
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
OPTIMASS 1000 T6 / 1010C T6 with or without heating jacket / insulation
Ambient Temp.
T
amb
°C
Max. medium
temp. T
m
°C
Temperature Class
Max. Surface
Temp. °C
40
45 T6 T80
60 T5 T95
95 T4 T130
130 T3 – T1 T165
50
60 T5 T95
95 T4 T130
130 T3 - T1 T165
65
95 T4 T130
130 T3 - T1 T165
OPTIMASS 1300C T6 with aluminium converter housing & without heating jacket / insulation
Ambient Temp.
T
amb
°C
Max. medium
temp. T
m
°C
Temperature Class
Max. Surface
Temp. °C
40
45 T6 T80
60 T5 T95
100 T4 T130
130 T3 – T1 T155
50
60 T5 T95
100 T4 T130
130 T3 - T1 T160
60 60 T4 - T1 T95
65* 65 T4 - T1 T100
OPTIMASS 1300C T6 with aluminium converter housing & heating jacket / insulation
Ambient Temp.
T
amb
°C
Max. medium
temp. T
m
°C
Temperature Class
Max. Surface
Temp. °C
40
45 T6 T80
60 T5 T95
95 T4 T130
130 T3 – T1 T165
50
60 T5 T95
95 T4 T130
100 T3 - T1 T135
60 60 T4 - T1 T95
65* 65 T4 - T1 T100
2.4 OPTIMASS 1000 T6 / 1010C T6 / 1300C T6
The OPTIMASS 1000 T6 / 1010C T6 / 1300C T6 is suitable for temperature classes T6….T1
according to the following table:
AD OPTIMASS 300_010 Haz Areas Rev 01.qxp 05/03/2014 13:24 Page 19