43
Carriers
Particular care is required when
adjusting the knife stop. The knives are
extremely sharp. Risk of injury.
The carriers (1) should have the 2distances shown in the
adjacent diagram a = 38 mm and b = 20 mm.
Knife Stop
Particular care is required when adjusting the knive stop. The knives are extremely sharp. Risk
of injury.
The position of the knives (1) on the double binding twine
guide can be altered by twisting the excenter disks
(2).To do this, undo the nuts (3). Bring the excenter disk
into the desired position and tighten up the nuts again.
Should the twine not be cut simultaneously although the
knives are sharp, the later of the two blades to cut the
twine should be positioned further outwards using the
excenter disk.
KR-0-115
2
1
1
b
a
KR-0-064
1
2
3