1 Supplementary Operating Manual
38 of 48
AmaControl
2301.83/04-EN
Start End Description Data type
11076 11076 Sum over lifetime:
temperature sensor 1
Warning
The following event numbers are counted: {123}
u 16bit
11114 11114 Sum over lifetime:
power reset
Message
The following event numbers are counted: {1}
u 16bit
11115 11115 Sum over lifetime:
synchronisation of real-time clock
Message
The following event numbers are counted: {252}
u 16bit
11117 11117 Sum over lifetime:
reset via switching input
Message
The following event numbers are counted: {254}
u 16bit
11118 11118 Sum over lifetime:
successful parameter change
Message
The following event numbers are counted: {249}
u 16bit
11172 11172 Current running time of the motor
0..65,535minutes
u 16bit
11174 11174 Number of running times <5minutes
Number to determine the quasi-percentage distribution
u 16bit
11175 11175 Number of running times 5 - 9minutes
Number to determine the quasi-percentage distribution
u 16bit
11176 11176 Number of running times 10 - 19minutes
Number to determine the quasi-percentage distribution
u 16bit
11177 11177 Number of running times 20 - 29minutes
Number to determine the quasi-percentage distribution
u 16bit
11180 11180 Number of running times 120 - 300minutes
Number to determine the quasi-percentage distribution
u 16bit
11181 11181 Number of running times > 300minutes
Number to determine the quasi-percentage distribution
u 16bit
11192 11192 Total number of starts of the current day (internal time)
0...255
u 16bit
11194 11194 Total number of starts of the previous day (current day - 1 day; internal
time) 0…255
u 16bit
11195 11195 Total number of starts two days ago (current day - 2 days; internal time)
0...255
u 16bit
11196 11196 Total number of starts three days ago (current day - 3 days; internal time)
0...255
u 16bit
11197 11197 Total number of starts four days ago (current day - 4 days; internal time)
0...255
u 16bit
11198 11198 Total number of starts five days ago (current day - 5 days; internal time)
0...255
u 16bit
11199 11199 Total number of starts six days ago (current day - 6 days; internal time)
0...255
u 16bit
11200 11200 Switching cycles of the current hour (internal time)
0...255
u 16bit
11201 11201 Maximum of the switching cycles per hour of the current day (internal
time) 0...255
u 16bit
11202 11202 Maximum of the switching cycles per hour of the previous day (current
day - 1 day;
internal time)
0...255
u 16bit