Omega
39
Trouble--shooting Table
Pump pressure too low
Pump pressure too high
Flow rate too high
Flow rate too low
Power consumption too high
Pump fails to pump liquid after being switched on
Pump ceases to pump liquid
Pump does not run smoothly (noise, vibrations)
Inadmissible temperature increase at pump /
seal casing
Bearing temperature too high
Exessive leakage at shaft seal
Drive overloaded
Leakage at pump
Cause Remedy
1
)
F F
In star / delta operation
motor hangs at star sta-
ge
Check electrical connections
Check switchgear.
F F F
Inadmissible air or gas
content in liquid
Vent
Check integrity of suction pipe, seal if
necessary
F F F F F
Air drawn in at pump in-
let
Correct suction conditions
Reduce flow velocity at suction pipe en-
try
Increase suction head
Check integrity of suction pipe and seal,
if necessary
Replace defective pipes.
F
Cavitation (rattling noise) Correct suction conditions
Check mode of operation
Increase suction head
Install pump at a lower level
F F
Foundation not rigid
enough
Check
Alter
F F F F F
Inadmissible parallel
operation
Re-- adjust operating point
Alter pump characteristic H
1).
F F
Shaft is out of true Renew / Replace
F F F F
Impeller rubs against ca-
sing components
Check rotor
Check impeller position
Check that the piping is connected wi-
thout transmitting any stresses or
strains.
1
) Consult KSB