A B C D E F G H Possible cause
Remedy
23)
✘ ✘
Speed is too high.
Reduce speed.
24)
✘
Defective gasket Fit new gasket between volute casing and
discharge cover.
✘
Worn shaft seal Fit new shaft seal.
Check flushing liquid/barrier fluid.
✘
Vibrations during pump operation Correct suction conditions.
Re-align the pump.
Re-balance the impeller.
Increase pressure at the pump suction nozzle.
✘
✘ ✘
The pump set is misaligned. Re-align.
✘
✘ ✘
Pump is warped or sympathetic
vibrations in the piping.
Check the piping connections and secure
fixing of pump; if required, reduce distances
between the pipe clamps.
Fix the pipelines using anti-vibration material.
✘
✘
Insufficient or excessive quantity of
lubricant or unsuitable lubricant.
Top up, reduce or change lubricant.
✘
Non-compliance with specified
coupling distance
Correct distance according to general
arrangement drawing.
✘ ✘
Motor is running on two phases only. Replace the defective fuse.
Check the electric cable connections.
✘
Rotor out of balance Clean the impeller.
Re-balance the impeller.
✘
Defective bearing(s) Fit new bearing(s).
✘ ✘ Flow rate is too low. Increase the minimum flow rate.
✘
Incorrect inflow of circulation liquid. Increase the free cross-section.
23)
Pump pressure must be released before attempting to remedy faults on parts which are subjected to pressure.
8 Trouble-shooting
RPH
61 of 76