1.4.1 Hazard Information
1.3.4.Setting of Warning Sign for Safety
This sign indicates a hazardous situation which, if not avoided,
could result in death or serious injury!
This sign shows danger of hot surface!
Refer to the operating instructions.
The Storion BluE-H5/H3 must not be touched or put into service until
5 minutes after it has been switched off or disconnected to prevent
an electric shock or injury.
During instruction, maintenance and repair, follow the instructions below to prevent
non-specialist personnel from causing misuse or accident:
Obvious signs should be placed at front switch and rear-level switch to prevent
accidents caused by false switching.
Warning signs or tapes should be set near operating areas.
The system must be reinstalled after maintenance or operation.
To ensure the electrical parameters to match requirements, related measuring
equipment are required when the system is being connected or tested.
Ensure that the connection and use matched specication to prevent electric arcs or
shocks.
It is very likely that moisture may cause damages to the system. Repair or maintaining
activities in wet weather should be avoided or limited.
The battery system is part of the energy storage system which stores life-threatening high
voltage even when the DC side is switched o. Touching the battery outlets is strictly
prohibited. The inverter can keep a life-threatening voltage even after disconnecting it
from the DC and / or AC side. Therefore, for safety reasons, it must be tested with a
properly calibrated voltage tester before an installer works on the equipment.
Exempt from classication according to Australian WHS regulations.
Classification of the hazardous chemical
Other hazards
This product is a Lithium Iron Phosphate Battery with certied compliance under the
UN Recommendations on Transport of Dangerous Goods, Manual of Tests and
Criteria, Part III, subsection 38.3. For the battery cell, chemical materials are stored in
a hermetically sealed metal case, designed to withstand temperatures and pressures
encountered during normal use. As a result, during normal use, there is no physical
danger of ignition or explosion and chemical danger of hazardous materials' leakage.
However, if the product is exposed to a fire, added mechanical shocks, decomposed,
added electric stress by misuse, the gas release vent will be operated. The battery cell
case will be breached at the extreme. Hazardous materials may be released.
Moreover, if heated strongly by the surrounding fire, acrid or harmful fume may be
emitted.
5min
1.3.5 Measuring Equipment
1.3.6 Moisture Protection
1.3.7 Operation After Power Failure
05
www.kstar.com
06
www.kstar.com
1.4 Battery Safety Datasheet
User Manual User Manual
1.4.2 Safety Datasheet
For detailed information please refer to the provided battery safety datasheet.