INV Abnormal
F18
(1) Please contact the distributor.
Communication Fault F32
Grid Fault
W00
W01
W02
W03
Solar Loss W04
Bat Loss W05
Bat Volt Low
W06
W07
Bat Volt High W08
Over Load Warning
W09
GFCI Over
W10
Fan Fault
W12
BMS Fault
W14~W27
(1) Please contact the distributor.
71
72
Product Specifications
10
(1) Restart the inverter and wait until it functions normally.
(2) Contact customer service if error warning continues.
(1) Check if the local voltage and frequency is in
compliance with the machine specification;
(2) If voltage and frequency are within the accepted
range, then wait 2 minutes for the inverter to function
normally; but if no recovery or fault repeats, please
contact the local inverter customer service;
(3) Contact the local power company if voltage and
frequency are beyond range or unstable.
(1) PV is not connected;
(2) Check grid connection;
(3) Check PV availability.
(1) Battery is not connected;
(2) Check if battery wiring port is short circuited;
(3) Contact customer service if error warning continues.
(1) Check the battery availability;
(2) Contact customer service if error warning continues.
(1) Check if the battery is in line with the presetting;
(2) If so, power off and restart;
(3) Contact customer service if error warning continues.
(1) Wait one minute for the inverter to restart;
(2) Check whether the load is in compliance with the
specification;
(1) Check PV string for direct or indirect grounding
phenomenon;
(2) Check peripherals of machine for current leakage;
(3) Contact the local inverter customer service if fault
remains unremoved.
(1) Restart the inverter and wait until it functions normally.
(2) Contact customer service if error warning continues.
Types
Codes Solutions
Battery Type
LFP (LiFePO4)
Maximum Charging Current
Maximum Discharging Current
Operating Temperature Range
0% ~ 95%(No condensation)
Humidity
Communication
Modules Connection
Monitoring Parameters
Max. 8 batteries in parallel
CAN and RS-485 compatible
System voltage, current, cell voltage,
cell temperature, PCBA temperature measurement
Passive Cooling
Ventilation Type
Operating Voltage Range
Energy Capacity
Depth of Discharge (DoD)
Rated Voltage
90%
5.12kWh
44.8~56.5Vdc
51.2V
50A (0.5C)
80A (0.8C)
0℃~+50℃
-10℃~+50℃(Built in heating film)
Battery Specifications
PACK5.1
Electrical
Operation
BMS
User Manual User Manual
LN Reverse
W11
(1) Check whether the installation follows the instructions;
(2) Contact customer service if error warning continues.
CT Reverse
W28
(1) Perform CT self-check;
(2) Contact customer service if error warning continues.
Grid VoltLock
Fail
W29
(1) Restart the inverter and wait until it functions normally.
(2) Contact customer service if error warning continues.
PV off
W30
(1) Restart the inverter and wait until it functions normally.
(2) Contact customer service if error warning continues.
System Reset
W31
(1) Restart the inverter and wait until it functions normally.
(2) Contact customer service if error warning continues.