Maintenance and storage
Mower conditioner
FC302RG - FC352RG
65
KN271BGB C
Lower gearbox:
- Remove breather plug (1) and its seal.
- Place a container of sufficient capacity under drain
plug (2).
- Remove drain plug (2) and its washer.
- Allow oil to drain completely.
- Wait for dripping to stop.
- Clean and reinstall drain plug (2) and its
washer. (Replace if necessary).
- Pour the correct oil quantity and quality through the
opening of the filler plug (1).
- Clean and reinstall breather plug (1) and its
seal. Replace if necessary.
- Check oil level in lower gearbox:
Remove level plug (3).
The oil level must reach the lower edge of level
hole (3).
Top up if necessary.
Clean and reinstall level plug (3) and its
seal. Replace if necessary.
Before draining oil, operate the machine for a
few minutes so that the oil warms up.
The lower gearbox is lubricated with 2.5 L (0.66 US gal) of extreme-pressure gear oil with SAE 80W
viscosity grade API and GL4.
When draining and refilling, it is recommended to use either a mineral base oil with viscosity grade
SAE 80W and API grade GL4, or a synthetic base oil, type PAO (Poly-Alpha-Olefins) with a viscosity
grade equivalent to SAE 80W.
In certain countries SAE 80W GL4 oil may not be available. In this case a GL4 or GL5 grade SAE 80W90
oil is an acceptable substitute for GL4 SAE 80W oil.
1
2
3