EasyManua.ls Logo

Kurzweil PC3 - The TRIM Page

Kurzweil PC3
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10-12
Keymap and Sample Editing
Editing Samples
The TRIM Page
TheTRIMpageletsyousettheStart,AlternativeStart,Loop,andEndpointsofthecurrent
sample.ThetoplineindicatestheZoomandGainsettings.ThisGainsettingdoesn’taffectthe
amplitudeofthesample,justtheviewinthedisplay.Therightsideofthetoplinedisplays
the
rootnumberofthesample.Ifthesampleispartofagroupofsampleroots,youcanusethe
Chan/Layerbuttonstoscrollthrougheachsampleinthegroup.
ThefourparametersonthispageareStart(S),AlternativeStart(A),Loop(L),andEnd(E).
Selectingthese
parametersandadjustingtheirvaluesenablesyoutomodifyhowthesample
playsbackwhennotesaretriggered.Eachoftheseparameterpointsareexpressedinindividual
samples.Forexample,aonesecondsampleatasamplerateof44,100Hzwouldhave44,100
valuesavailabletoadjustforeachofthese
parameters.
Thereisaverticallineinthecenterofthedisplayindicatingthe placementofthecurrent
parameterinthesamplewaveform.Thesamplewaveformwillmoverelativetothelinewhen
eachparameterisselectedoradjusted.Thelineremainsinthecenterofthedisplay,andthe
waveform
shiftstoindicatethenewpositionofthepoint.Eachparametercanbeadjustedwith
the‐/+buttons,theAlphaWheel,orthealphanumericbuttonpadfollowedbytheEnterbutton.
TheStart(S)pointdeterminesthebeginningofthecurrentsample.Youcantruncatethe
beginningofthesampleby
increasingthevalueoftheStart(S)parameter.Youmightdothisto
removesilenceatthebeginningofasample,ortoremovesomeoralloftheattack.Youcan’t
decreasetheStartpointofsamplesbelowzero.
TheAlternativeStart(A)parameterletsyousetasecond,
optionalstartorendpointforthe
currentsample.TheAlternativeStartwillbeusedwhentheAltSwitchparameteronthe
KEYMAPpageissettoOn,orwhenit’ssettoaspecif iccontrolsourceandthatcontrolsourceis
generatingavalueofmorethan+.5.(For
example,ifyouassignMWheelasthecontrolsource
fortheAltSwitchparameter,theAlternativeStartwillbeusedwhentheModWheel—or
whatevercontrolsourceyouhavesettosendMWheel—isaboveitshalfwaypoint.)The
AlternativeStartcanbesetbefore,after,oratthesamepointas
theStartorEnd.
IfyousettheAlternativeStartaftertheEnd ,youcanextendtheplayofloopedsamples.
Normally,loopedsampleswillplaythroughtotheEnd,thenwillloopbacktotheLooppoint,
andcontinueloopinglikethisuntilthenoteisreleased,whentheygo
intotheirnormalrelease.
IftheAlternativeStartissetaftertheEnd,loopedsampleswillloopinthesamewaywhilenotes
aresustained.Assoonasyoureleasethenotes,however,thesampleswillplaythroughtothe
AlternativeStartpointbeforegoingintorelease.
TheLoop(L)parameter
setsthebeginningoftheloopedportionofthecurrentsample.The
LoopcanbesetatanypointbeforetheEnd,includingbeforetheStartandAlternativeStart.If
youtrytomoveitaftertheEnd,theEndwillmovewithit.Whenyou’resettingaloopsegment
forasample,youshouldadjustboththeLoopandEndparameterssothatthetwoendsofthe
waveformwouldmeet(orcomeascloseaspossible)whentheloopoccurs.Youcandothis
visuallybyzoominginclosetothewaveform(untilitbecomesasingleline,)then
adjustingthe
LoopandEndparametersofthewaveformuntilbothendsarethesamedistanceaboveorbelow

Table of Contents

Other manuals for Kurzweil PC3

Related product manuals