2MW/2MX
1-4-5
5011 Bridge conveying sensor 3
stay jam
The bridge conveying sensor 3 (BRCS3) does not
turn off during paper feed from cassette 1.
J
5012 The bridge conveying sensor 3 (BRCS3) does not
turn off during paper feed from cassette 2.
J
5013 The bridge conveying sensor 3 (BRCS3) does not
turn off during paper feed from cassette 3.
J
5018 The bridge conveying sensor 3 (BRCS3) does not
turn off during paper feed from duplex section.
J
5019 The bridge conveying sensor 3 (BRCS3) does not
turn off during paper feed from MP tray.
J
6023 Staple cover open The staple cover is opened during operation. K
6043 DF top cover open The DF top cover is opened during operation. K
6103 DF paper conveying sensor
non arrival jam
The paper conveying sensor (PCS) does not
turned on even if a specified time has elapsed after
the machine eject signal was received.
J
6113 DF paper conveying sensor
stay jam
The paper conveying sensor (PCS) does not turn
off within specified time of its turning on.
K
6123 DF paper conveying sensor
remaining jam
The paper conveying sensor (PCS) does turned on
when the power is turned on or cover close.
K
6413 DF eject paper sensor stay
jam
The eject paper sensor (EPS) does not turn off
within specified time of its turning on.
K
6423 DF eject paper sensor
remaining jam
The eject paper sensor (EPS) does turned on
when the power is turned on or cover close.
K
6803 Front adjustment plate oper-
ation ON error
The adjustment sensor 1 (ADS1) does turned on
when job is executed.
K
6813 Front adjustment plate oper-
ation OFF error
The adjustment sensor 1 (ADS1) does turned off
when job is executed.
K
6903 Rear adjustment plate oper-
ation ON error
The adjustment sensor 2 (ADS2) does turned on
when job is executed.
K
6913 Rear adjustment plate oper-
ation OFF error
The adjustment sensor 2 (ADS2) does turned off
when job is executed.
K
7013 Staple operation error The next staple hasn't head-poked for the next
copy to bind after a predetermined interval while
clinching has commenced.
K
7023 Staple initial operation error Head-poking has not been accomplished after 10
attempts in the initialization at power up or closing
the cover.
K
7913 Sequence error 1
(operation prohibited)
Operation commenced in the state the finisher is
prohibited to operate.
K
7923 Sequence error 2
(initialoperation error)
A request for maintenance mode has occurred in
the state the finisher is prohibited to operate or has
commenced operation.
K
Code Contents Conditions
Jam