2MW/2MX
1-3-39
U100 Setting the main high voltage
Description
Performs main charging.
Purpose
To check main charging.
Method
1. Press the start key.
2. Select the item. The screen for executing each item is displayed.
Method:[Main charger/Laser]
1. Press the start key.
2. Select [Execute] and press the start key.The operation starts.
Setting: [DC Bias]
1. Select an item to be set.
2. Change the setting value using the cursor left/right keys or numeric keys.
3. Press the start key. The value is set.
Item No. Description
Display Description
Main charger Confirming of main motor driving and main charger operating
Laser Confirming of laser operating
DC Bias DC bias setting
Idc Bias Idc bias setting
Set Low Temp Control setting of main charger (At the low temperature)
Display Description
Setting
range
Initial
setting
Full DC bias regulations value at the full speed
(Only the display)
0 to 255 -
Half DC bias regulations value at the half speed
(Only the display)
0 to 255 -
Adj Full DC bias setting value at the full speed -500 to 500 0
Adj Half DC bias setting value at the half speed -500 to 500 0