Loading...
2MW/2MX
1-3-40
U100 Setting: [Idc Bias]
1. Select an item to be set.
2. Change the setting value using the cursor left/right keys or numeric keys.
3. Press the start key. The value is set.
Setting: [Set Low Temp]
1. Select an item to be set.
2. Press the start key. The value is set.
Completion
Press the stop key when main charger output stops. The screen for selecting a maintenance item
No. is displayed.
Item No. Description
Display Description
Setting
range
Initial
setting
Full Idc bias regulations value at the full
speed (Only the display)
0?255 -
Half Idc bias regulations value at the half
speed (Only the display)
0?255 -
Adj Freq Setting value of bias frequency 1000?4000 1800
Display Description
On Setting of main charger :On (At the low temperature)
Off Setting of main charger :Off (At the low temperature)