2GL/2FV/2FW
1-6-15
1-6-6 PWBs
(1) Detaching and refitting the main PWB (16 ppm GDI printer)
<Procedure>
1. Remove the right cover. See page 1-6-2.
2. Remove the two connectors from main
PWB.
3. Remove one screw from the USB interface
connector.
4. Remove the three screws and then remove
the main PWB.
Figure 1-6-21
Main PWB
USB interface
connector
Screw
Screw
Screw
Screw
Connectors