Operation
Setting to standby mode
To reduce the electrical consumption, the amplied controller can be put in standby mode.
Use LA Network Manager to set the amplied controller to standby or back to operating mode. Refer to the LA
Network Manager video tutorial.
An amplied controller in standby mode displays Standby mode and its POWER LED is lit in orange.
Standby mode can also be cancelled from the amplied controller front panel by pushing and holding the encoder wheel
for one second.
Interpreting the front panel LEDs
STATUS
The STATUS LED on the front panel displays the state of the amplied controller.
— green: when the LA4X operates normally
— red: during rmware update or when a fault is detected in the LA4X circuitry, indicating a protection system is active.
Refer to Error messages (p.53)
L-NET
The L-NET LED on the front panel displays the L-NET status.
— green: when the LA4X is remotely controlled by software such as LA Network Manager (refer to the LA Network
Manager video tutorial).
— off: when no software remotely controls the amplied controller.
The front panel commands remain accessible when the L-NET LED is lit.