Maintenance
Other messages
System Message
Update error
Displayed if the rmware update has failed. Try to restart the amplied controller. If
the issue persists, check that each L-NET cable is in working order and is correctly
plugged on both ends and relaunch the update process. If the issue persists, contact
L-Acoustics.
High temp on ch #
Channel attenuated
Displayed if temperature at an output channel is above 60° C. The signal delivered
at the output channel is attenuated until temperature returns to nominal conditions.
Over temp on ch #
Channel muted
Displayed if temperature at an output channel is above 65° C. The signal delivered
at this output channel is muted until the temperature returns to nominal conditions.
System Message
Fan blocked
Displayed if a fan is faulty. The controller remains operational but there is a risk of
temperature rising.
For temperature messages:
possible cause diagnosis / procedure
room temperature is too high / too low
make sure room temperature is within amplied controller
operating condition range (0º C / 32º F to +50º C / 122º
F)
foam lter clogged, inside of amplied controller dusty
clean or replace the foam lter, clean the amplied
controller with an air blower
amplied controller is not getting enough cool air
install the amplied controller in an open area so that
the front and rear panels are not blocked by an external
objects or structure.
If rack-mounted:
— do not block the ventilation grill with front and back
panels or doors, or use a forced ventilation system
— when stacking more than one amplied controller,
mount them directly on top of one another or close the
free spaces with blank panels
channel resources are solicited to their limits
monitor the channel LED meter: in case of persistent high
level or clip, reduce the audio source output level (refer to
the third-party documentations) or the gain value on the
channel.
loudspeaker impedance too low
check that nothing causes a short-circuit at the output
(incorrect cabling scheme, damaged cable or short-circuit
in the speaker voice coil).
Glossary
CE Europe
CHK check procedure
CN China
D/R disassembly/reassembly procedure
INSP inspection procedure
INT international (bare lead version of the power cable)
KR repair kit
N.m newton meter, international torque unit, 1 N.m = 9 in lbf
SMPS Switched Mode Power Supply (power supply inside of the amplied controller)
US United States