INSTRUCTIONMANUALFORTHEINSTALLER
Theelectricheatingsystemofthemachineisalreadysetbythemanufacturertoworkatatemperatureof
intheboiler,correspondingtoboilerpressure.Thispressurecanbeviewedonthepressure
gauge(4)ontheappliance.
Toincreaseordecreaseboilerpressure,itisnecessarytoadjustthemechanicalpressureswitch(Pict8)
insidetheappliance(ontherightside)asfollows:
• To increase boiler pressure, turn the adjustment
screwanticlockwise.
• To decrease boiler pressure, turn the adjustment
screwclockwise.
Boilerpressure(operatingtemperature)isusuallymodied exclusivelyinordertoadaptthemachine
temperaturetothetypeofcoffeeblendused,soastoimprovetheresultinthecup.
Pressthecupwarmeroperatingbutton (24)andcheckitsoperatingstatusthroughthelightingupof
theLED(23)onthecontrolpanel.Toswitchitoff,pressthesamebutton.
008
ADJUSTMENT SCREW
PRESSURE SWITCH